| Item |
Test Criteria |
| Temperature |
IEC 68-2-1,2,14
/ MIL-STD-810F Method 501.4, 502.4
• Operating: 0XC to 55XC -20 XC
to 55 XC (Optional)
• Non-operating: -40XC to 70XC |
| Humidity |
According to IEC 68-2-30 / MIL-STD-810F
Method 507.4 5% to 95% RH; non-condensing |
| Altitude |
According to IEC
68-2-13 / MIL-STD-810F Method 500.4
• Operating: 15,000ft
• Non-operating: 40,000ft
• altitude change rate: 2,000 ft/min |
| Shock |
According to IEC 68-2-27 / MIL-STD-810F
Method 516.5
• Operating: 15g, 11 ms, half sine
wave
• Non-operating: 50g, 11 ms, half
sine wave |
| Drop |
According to IEC 68-2-32 / MIL-STD-810F
Method 516.5;
3 Feet height free drop
Test surface: steel plate |
| Vibration |
According to IEC 68-2-6 Sinusoidal wave vibration
• Operating: 10~55Hz/0.075,
55~500Hz/1.0g
• Non-operating: 10~55Hz/0.15,
55~500Hz/2.0g
• Random vibration: MIL-STD-810F,
514.5 - high way truck vibration exposure |
| ESD |
According to IEC1000-4-2
• Air Discharge: 0KV~8KV(included),
no error 8KV~15KV, allow soft error
• Contact Discharge:0KV~4KV(included),
no error 4KV~ 8KV, allow soft error |
| Enclosure |
According to IEC
529 / MIL-STD-810F; IP51 |
| Regulation |
FCC part 15, Subpart
B, Class B, UL, TUV, CE, CCC, WHQL,
BSMI, EMARK |